Model 3000 & Access 4000 Single Door-2 Door
The Reader Module is designed to provide Interfacing for two Reader heads along with all input and output requirements for the control and monitoring of:
- A Single Door using Entry and/or Exit Readers with Entry/Exit button options
- Two separate Doors each using one Reader only, with Exit button options
Single Door or 2 Door Mode is selectable in the Reader Module programming options.
The versatile hardware and software design allows for each Reader to be configured independently, even allowing for mixed reader technologies to be used on the same module. Heavy duty relays are provided on-board for lock switching, along with Auxiliary outputs for "Valid", "Invalid" or "Door Open Too Long Warning*" to control Reader LEDs and/or Buzzers. (*V13 or later Reader firmware and V3 or later Control Module firmware required)
Simple Programming options allow for Door Access Control to be integrated with Area On/Off Control where required. Access Control processing utilizes the Door Contacts and/or Tongue Sense inputs to provide "Door Forced" and "Door Open Too Long" alarms and spare Zone inputs are available for PIRs, PE beams, and other detection devices.