The timed zone, zone 1 and zone 2 circuits all have a similar connection format, and can each be used with normally closed circuit devices (magnetic contacts, space protectors, e.g. passive infra-red, foil, etc) and normally open circuit devices (pressure pads). Each circuit is served by a four way terminal connector, with a convenient set of terminals for the tamper circuit.

Each circuit is provided with its own fault indicator and when any circuit has caused an alarm condition, all other circuit indicators will be locked out creating a "First to latch indicator".

As supplied the unit is completed with service links in the connector terminas. The links simulate a closed circuit across the zone inputs for testing, so when any zone is to be used for closed circuit devices the link for that zone should be removed.