Omnicron 8000 Home Security Installation

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | Search

Preview: Omnicron 8000 Home Security Installation

Click here for full document

The control panel is designed to be simple to install, programme, and to use. The 16 button keypad allows you to select, change, or inhibit with ease, the many facilities available in the unit. The keypad, remote keyswitch or remote keypad (both purchased separately) can be used to arm and disarm the control panel.

The control panel is programmed using either the user code (factory set 1234) or the engineer code (factory set 9999). It is advisable to change both code numbers to a personally selectable code, using any combination from 0000 to 9999, when the installation is complete.

The user and engineer programmes are protected by a Non Volatile Memory (NVM). This means that when all power has been removed and then reconnected any previously programmed information remains operative. The NVM facility also protects the control panel microchip from mains surges and spikes.

The control panel provides 5 detector zones, a personal attack circuit and two tamper circuits. Zone 5 can be programmed as a fire zone. Any or all of the detector zones can be selected as the entry/exit zone, and all zones are capable of operation with normally open and normally closed detectors. A bank of 9 led indicators will indicate the status whilst programming or whilst in use.

An integral battery charge circuit will enable a rechargeable battery (not supplied) to provide power during mains failure. Outputs are provided for bell/sounder, RSCB, strobe and + set. Three communicator outputs are also provided.

The 5 detector zones are active only when the control panel is armed. The personal attack circuit, 24hr and SCB circuits (and zone 5 is programmed as a fire zone) are active 24 hrs a day even if the control panel is disarmed.

Click here for full document